Our old
faithful switch design is still best where highest
precision combined with diaphragm sealed leak proof construction
and mounting simplicity are required. Model 1626 and 1627
differential pressure switches are identical in design and
construction except that Model 1626 has a single electric
switch and Model 1627 has dual electric switches. Model
1627 can therefore provide dual control when required. It
can be set to open or close two independent electrical circuits,
each preset for its own actuation pressure. Both units have
diaphragm sealed motion take outs providing maximum protection
against leakage.
CAUTION:
FOR USE ONLY WITH AIR OR COMPATIBLE GASES.
SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Temperature Limits: -30 to 130°F (-34.4 to 54.4°C).
Pressure Limits: Max. 50 in. w.c. (12.44 kPa) continuous,
2 psig (13.79 kPa) surge.
Switch Type: 1626, single-pole double throw (SPDT);
1627, two single-pole double throw (SPDT).
Repeatability: ±1%.
Electrical Rating: 15A @ 120-480 VAC, 60 Hz. Resistive,
1/8 HP @ 125 VAC, 1/4 HP @ 250 VAC, 60 Hz.
Electrical Connections: 3 screw type, common, normally
open and normally closed.
Process Connections: 1/8" female NPT.
Mounting Orientation: Diaphragm in vertical position.
Consult factory for other position orientations.
Set Point Adjustment: Screw adjustment.
Weight: Model 1626, 3 lb 9.8 oz (1.64 kg); Model
1627, 3 lb 11.8 oz (1.69 kg).
Agency Approvals: CE.
|