Single Pressure Transmitters
 

The 619 Series Pressure Indicating Transmitter simultaneously provides local indication on a large, easily read 3-1/2 digit liquid crystal display while also converting that pressure into a standard 2-wire, 4-20 mA signal for ranges from 0-15 to 0-500 psi. Positive pressure is measured to the accuracy of ±0.5% of full scale. The electrical signal and conditioning is produced by a piezoresistive pressure cell for precision measurement of compatible gases and liquids. A 316 stainless steel connection block features convenient 1/4" female NPT and 1/2" male NPT pressure connection.


SPECIFICATIONS
Service: Compatible, gases & liquids.
Wetted Materials: Type 316L SS.
Accuracy: ±0.5% F.S. (includes linearity, hysteresis & repeatability).
Stability: ±1% F.S./yr.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Pressure Limit: 2 x maximum range.
Thermal Effect: ±0.025% F.S./°F (0.045% F.S./°C).
Power Requirements: 10 to 35 VDC.
Output Signal: 4 to 20 mA.
Display: 1.0" (25.4 mm) liquid crystal. 3-1/2 digits.
Zero and Span Adjustments: Accessible potentiometers on back.
Loop Resistance: 1250 ohms DC max.
Current Consumption: 38 mA DC max.
Electrical Connections: Screw-type terminal block.
Process Connection: Dual 1/4" female NPT 1/2" male NPT, bottom connection.
Enclosure Rating: Designed to meet NEMA 1.
Mounting Orientation: Vertical.
Weight: 1 lb 8 oz (680 g).

 