The Series
636D Differential Pressure Transmitter can be
used for measuring pressures of liquids, gases & vapors.
All available ranges have an excellent 0.5% F.S. accuracy
with a 4-20 mA Output standard or optional 1-5 VDC output.
The NEMA 4 housing is an all 316 welded construction that
is designed to withstand the harshest environmental conditions.
With all 316L wetted materials, this transmitter is compatible
with most media. These units are CSA approved explosion-proof
for use in the specified hazardous locations and meet NACE
standards for off-shore applications.
APPLICATIONS
Monitoring Differential Pressure for:
- Oil & Gas Applications
- Level Measurements in Non-Vented Liquid Tanks
- Filtration Systems
- Compressor Control
- Process Control
SPECIFICATIONS
Service: Compatible gases, liquids or vapors.
Wetted Materials: Types 316L SS.
Accuracy: BFSL: ±0.5% F.S. (includes linearity, hysteresis
& repeatability).
Stability: ±1.0% F.S./yr.
Pressure Limits: 3 x full scale differential pressure;
Burst: 2500 psig.
Temperature Limits: Ambient Operating: -40 to 140°F
(-40 to 60°C); Process Interface: -40 to 212°F (-40 to 100°C);
Storage: -40 to 212°F (-40 to 100°C).
Compensated Temperature Range: -20 to 160°F (-29
to 71°C).
Thermal Effect: ±2% F.S./50°F (reference to 77°F).
Power Requirements: 12-30 VDC for 4-20 mA outputs;
8-14 VDC for 1-5 VDC outputs, both with reverse polarity
protection.
Output Signal: 4 to 20 mA DC or 1-5 VDC.
Zero and Span Adjustments: Fixed.
Response Time: 20 ms.
Loop Resistance: 900 ohms max. @ 30 VDC for current
outputs. For voltage outputs, minimum lead resistance 50k
ohms.
Current Consumption: 4-20 mA for current output models;
3 mA for voltage output models.
Electrical Connections: 2 ft, 22 AWG cable; 3/4"
female NPT conduit.
Process Connection: Two 1/2" female NPT.
Enclosure Rating: NEMA 4 (IP65).
Mounting Orientation: ±0.05 psi/90° rotation from
horizontal.
Weight: 1.8 lb (0.82 kg).
Agency Approvals: CSA approved explosion-proof for
Class I, Division 1, Groups B, C and D; Class II, Groups
E, F, and G; Class III.
|