Four
Input, 1/8 DIN annunciator
is ideal for any application where pressure, temperature,
level or flow switches require visible and audible alarms.
Two annunciators can be easily wired together to form an
eight input system. Field selectable logic for ISA Sequence
A (momentary or maintained alarms) or ISA Sequence F2A (momentary
or maintained with first out). LED alarm and power indication
on a NEMA 4 from panel. 1.64" H x 3.59" W x 4.13" D (42
x 91 x 105 mm).
SPECIFICATIONS
Inputs: NO or NC switches; Open Collector Transistor
(Open circuit voltage = 5 VDC); Logic Levels: LO = 0 to
0.8 VDC, HI 4.7 to 28 VDC (100 kW input impedence).
Outputs: SPDT relay (5A @ 240 VAC, resistive), Audible
alarm (75 dB), four red indicating LEDs.
Ambient Operating Temperature: 14 to 149°F (-10 to
65°C).
Power Requirements: 117 or 230 VAC ±10%, 50/60 Hz,
3 VA.
Electrical Connections: Removable screw terminal
block, accepts 24 to 12 AWG.
Mounting: 1/8 DIN.
Housing Material: ABS plastic.
Enclosure Rating: NEMA 4 front panel.
Weight: 11.4 oz (325 g). |