Series
BT Bimetal Thermometers offer accurate, reliable
service even in the toughest environments. These corrosion
resistant units are constructed from stainless steel and
are hermetically sealed to prevent crystal fogging. The
bimetal element directly drives pointer, eliminating gears
and linkage. An external reset screw allows field calibration
and easy-to-read aluminum dial minimizes parallax error.
Choose back connection, lower connection or adjustable angle
for easy viewing and installation. Adjustable models can
be rotated a full 360° and tilted over a 180° arc. NOTE:
When using in pressurized applications, use a suitable thermowell.
SPECIFICATIONS
Wetted Materials: 304 SS.
Accuracy: ±1% full scale.
Response Time: = 40 seconds.
Temperature Limits: Head: 200°F (93°C). Stem: Not
to exceed 50% overrange or 1000°F (538°C) or 800°F (427°C)
continuously.
Process Connection: 1/4" NPT on 2" dial size; 1/2"
NPT on 3" or 5" dial size.
Materials of Construction: 304 Stainless Steel stem,
glass crystal, anodized aluminum dial, Series 300 Stainless
Steel head, bezel, and mounting bushing.
Stem Diameter: 1/4" O.D.
Immersion Depth: Minimum 2" in liquids, 4" in gas.
|