The Series
GVS offers accurate flow detection with 1% repeatability
and external adjustability over a broad range of flow settings.
The durable construction delivers long-life reliability
in either water or oil. Generous flow paths keep pressure
drop low. The GVS is ideal for detection of improper flow
rates in high volume lubrication, cooling or process systems.
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Housing: bronze; Shuttle: TFE;
Bonnet: bronze; Spring: 316SS; Other: Fluoroelastomer, ceramic.
Temperature Limits: -20 to 200°F (-29 to 93°C).
Pressure Limits: 400 psig (27 bar) @ 100°F (38°C).
Accuracy: ±10%.
Repeatability: 1% maximum deviation.
Switch Type: SPDT.
Electrical Rating: .17 A @ 120 VAC, .08 A @ 240 VAC,
.13 A @ 120 VDC, .06 A @ 240 VDC.
Electrical Connections: No. 18 AWG, 24" (61 cm) length,
Polymeric lead wires.
Process Connections: 1" female NPT.
Mounting Orientation: Any position. Set points shown
are based on horizontal, lead wires up position.
Required Filtration: 150 microns or better.
Weight: 2 lb 8 oz (1.16 kg).
|