The Series
PE Orifice Plate Flow Meter offers one-piece
PVC construction incorporating a unique holder or carrier
ring containing metering taps and integral gaskets. Unlike
a standard orifice plate, the Series PE is a true primary
element including the various components for differential
pressure measurement. It was designed for use wherever there
is an application for a conventional flow orifice plate.
It can also be used in place of other primary differential
producers for efficiency and cost effectiveness. The Series
PE is available in line sizes from 1/2" to 24" and used
for air and most gases. It meets or exceeds ASME, AGA &
ISO standards.
SPECIFICATIONS
Service: Clean air and compatible gases.
Wetted Material: Monolithic (single piece) constructed
entirely of gray PVC.
Accuracy: ±0.6% full scale flow. (Beta= .2-.6) ±0.7%
for Beta greater than .6.
Temperature: 140°F (60°C) max.
Pressure: 150 psi max.
Head Loss: 1 - Beta ratio˛, eg: 1 - 07˛ = 1 - 0.49
= 51% of the d.p.
Line Sizes: 1/2" to 24".
Process Connections: 1/4" female NPT.
Installation: Standard flange 125#/150# rating.
Pipe Requirements: General requirements 10 diameter
upstream and 5 diameter downstream.
Weight: Varies with line size. See "Ordering
Page".
FEATURES
- Mounted with standard flanges
- Standard "corner tap" configuration
- Corrosion free material
- Simplified installation
- Built in metering taps (1/4" female NPT STD)
- Proven through a wide range of applications for accuracy
and energy efficiency
- Assures long term reliability and accuracy
|