Simplify
your on-demand cleaning requirements with the
Series DCT1000 Dust Collector Timer Controller. Relying
on one timer board for on-demand and continuous cleaning
applications, the DCT1000 eliminates external devices such
as pressure switches, relays and timers.
Offering a universal power supply, the DCT1000
accepts 85-270 VAC/VDC at either 50 or 60 Hz for both domestic
and overseas requirements. The units modular design allows
for use as a continuous cleaning control or on-demand cleaning
control using the optional plug-in pressure module. A 4-20
mA process output is integral to the plug-in pressure module,
eliminating the need to purchase an expensive process transmitter.
Mounting holes are standard to other dust collector controllers
used in the industry, allowing you to use the DCT1000 for
existing installations.
In addition, the DCT1000 is the same size
for 6, 10 and 22 channels. One board size allows the standardization
on one enclosure. Latching relays and jumper wires are eliminated
for large installations requiring channel expanders. Each
channel expander connected is automatically detected.
SPECIFICATIONS
DCT1000 TIMER CONTROLLER:
Output Channels: 6, 10 & 22 channels. Expandable
to 255 channels using DCT1122 & DCT1110 channel expander
boards.
Power Requirements: 85 to 270 VAC, 50 or 60 Hz.
Power Consumption: 5 W.
Solenoid Supply: 3A maximum per channel.
Fuse: 3 A @ 250 VAC. Low voltage control circuitry
is isolated from the line voltage for system safety.
Temperature Limits: -40 to 140°F (-40 to 60°C).
Storage Temperature Limits: -40 to 140°F (-40 to
80°C).
On-time: 10 msec to 600 msec, 10 msec steps.
On-time Accuracy: ±10 msec.
Off-time: 1 second to 255 seconds, 1 second steps.
Off-time Accuracy: ±1% of the value or ±50 msec,
whichever is greater.
Weight: 1 lb, 3.0 oz (538.6 g).
Agency Approvals: UL, cUL.
DCP PRESSURE MODULE:
Pressure Ranges: 10" w.c. or 20" w.c.
Temperature Limits: -40 to 140°F (-40 to 60°C).
Pressure Limits: 10 psi (68.95 kPa).
Pressure Limits (differential): 10 psi (68.95 kPa).
Accuracy: ±1.5% F.S. @ 73°F (22.8°C).
Output Signal: 4-20 mA.
Alarm Contacts: 1.5A inductive load, 3A resistive
load @ 30 VAC or 40 VDC.
Process Connections: Two barbed connections for use
with 1/8" (3.18 mm) or 3/16" (4.76 mm) I.D. tubing.
Weight: 5.5 oz (155.9 g).
OPTIONS
-- Consult Factory for Pricing
WP-Weatherproof Housing Only
WPP-Weatherproof Housing with Pressure Ports
WPPS-Weatherproof Housing with Pressure Ports, Three
Position Rotary Switch Installed

EXPL-Explosion-proof Housing

Multiple Boards stacked in enclosure


DCA Channel expander cable available
in 1 ft, 2 ft, and 4 ft lengths