Monitor
and record AC current and voltage using
Model DL-AC to determine energy consumption. The DL-AC logger
has eight channels with four channels configured to accept
current input, three accept voltage input and one for ambient
temperature measurement. Use external clamp or current probes
(not included) to record alternating current. Sampling methods
and rates are user configurable. The logger can store up
to 21,500 readings. Stored data can be downloaded to a PC
using Model DL-200 software or remotely retrieve data by
modem.
SPECIFICATIONS
No. of Channels: Eight; one for internal thermistor,
four for AC current and three for AC voltage.
Internal Thermistor Range: -40 to 158°F (-40 to 70°C).
Memory Size: 21,500 readings.
Accuracy: ±0.5% F.S. @ 77°F (25°C).
Clock Accuracy: ±2 seconds per day plus one sampling
interval.
Resolution: 12 bits (1 in 4,096).
Sampling Methods: Continuous (first-in, first-out)
or stop when full (fill-then-stop).
Sampling Rates: Selectable from 0.04 seconds to once
every 8 hours.
Ambient Operating Temperature/RH: -50 to 160°F (-45
to 70°C), 0 to 95% RH, non-condensing.
Connection: Removable screw terminal.
Computer Requirements: IBM compatible running Windows®
3.1, Windows® 95, Windows® 98, Windows® 2000, Windows® ME,
Windows® NT, or Windows® XP with 2 MB RAM and 2 MB hard
drive disk space, one serial port.
Power Requirements: Built-in 3.6V Lithium battery.
Housing Material: Plastic.
Weight: 5 oz (110 g).
Agency Approvals: CE.
ACCESSORIES
-- See "Ordering" page
DL200 - Windows® Software
and Connecting Cable.
|