Use Series
DR Glass Flowmeters to accurately measure flow
rates of air or water with the convenience of a direct reading
scale. Permanently fused ceramic scale has integral float
guides for optimum float performance. Reflective plastic
background and 1.5 X magnification lens reduces eye fatigue
and allows for more accurate readings. Units include a safety
blow-out back panel for additional protection. Flowmeters
are shipped completely assembled and include standard panel
mounting hardware for quick installation.
APPLICATIONS
Glass flowmeters are suitable for metering gases or liquids
for film processing, paper manufacturing, chemical processing,
semiconductor industry, water and air pollution analysis
equipment, metals processing, industrial fuel and energy
conservation, cylinder gas metering, and general laboratory
and industrial applications.
SPECIFICATIONS
Service: Compatible gases or liquids.
Wetted Materials:
Flowtube: Borosilicate glass.
Float: 316 stainless steel (black glass as indicated).
Float Stops: PTFE.
End Fittings: Anodized Aluminum or 316 stainless steel.
O-rings: Buna-N on aluminum models and Fluoroelastomer on
stainless steel models.
Temperature Limits: 250°F (121°C).
Pressure Limits: 250 psig (17 bar).
Accuracy: ±5% FS @ 70°F (21.1°C) and 14.7 psia (1
atm absolute).
Repeatability: ±0.25% of scale reading.
Scales: Direct reading 65 mm or 150 mm scales for
air or water.
Turn-down ratio: 10:1.
Connection: 1/8" female NPT.
Mounting: Vertical.
Valve: 6-turn needle (standard on models with valve).
|