Series
GFC Gas Mass Flow Controllers combine a straight
tube sensor with a restrictor flow element to provide high
accuracy and repeatability. Flow rates are virtually unaffected
by temperature and pressure variations. Gas mass flow controllers
utilize an electromagnetic valve and PID electronics to
maintain continuous control by comparing measured sensor
signal set to flow rates. Setpoints can be adjusted with
local potentiometers or remotely via 0 to 5 VDC or 4 to
20 mA analog signal. Actual gas flow is displayed in engineering
units on a 3-1/2 digit, 90° tiltable LCD readout. Units
can be used with Series GFT Flow Totalizer for applications
requiring totalization. Series GFC includes a NIST traceable
certificate.
SPECIFICATIONS
Service: Clean gases compatible
with wetted parts.
Wetted Materials: GFC-1XXX: Anodized Aluminum, Brass,
316 SS and Fluoroelastomer O-rings; GFC-2XXX: 316 SS and
Fluoroelastomer O-rings.
Accuracy: ±1.5% FS including linearity over 59 to
77°F (5 to 25°C) and 5 to 60 psia (0.35 to 4 bar).
Repeatability: ±0.5% of full scale.
Response Time: 2 seconds to within ±2% of actual
flow.
Output: Linear 0-5 VDC and 4-20 mA.
Max. Particulate Size: 5 microns.
Temperature Limits: 32 to 122°F (0 to 50°C).
Power Supply: ±12 VDC.
Process Connections: 1/4" compression fitting for
flow rates =50 L/m; 3/8" for 100 and 200 L/m; 1/2" for 500
L/min; 3/4" for 1000 L/min.
Pressure Limits: 500 psig (34.5 bar).
Leak Integrity: 1 x 10-7 sccs of Helium.
Display: 90° tiltable, 3-1/2 digit.
Agency Approvals: CE.
ACCESSORIES -
See "Ordering" page
For Series GFC Gas Mass Flowmeters
GFC-110P - 110V
Power Supply
GFC-220PE - 220V Power
Supply
GFC-CBL1 - 8 ft cable
with 15-pin connector
GFC-CBL3 - 3 ft extension
cable for LCD readout
IO-1 - 0-5 VDC to RS232
Input to Output Signal Conditioner
|