Rugged
and reliable the Series L4 Flotect® Float Switch
operates automatically to indicate tank level. Perfect for
starting or stopping pumps, opening or closing valves, or
actuating level alarm signals. A unique magnetically actuated
switching design gives superior performance. There are no
bellows, springs, or seals to fail. Instead, the free-swinging
float attracts a magnet within the solid metal switch body,
actuating a snap switch by means of a simple lever arm.
Float arm hinge design limits the arm angle to prevent vertical
hang up.
APPLICATIONS
- Direct pump control for maintaining level
- Automatic tank dump operations
- Control levels or provide alarms in sumps, scrubber
systems, hydro-pneumatic tanks, low pressure boilers,
and various wastewater/sewage treatment processes
SPECIFICATIONS
Service: Liquids compatible with wetted materials.
Wetted Materials:
Float and Rod: 316SS.
Body: Brass or 316SS standard.
Magnet Keeper: 430SS standard, 316SS
or Nickel optional.
Temperature Limits: 4 to 275°F (-20 to 135°C) standard.
MT high temperature option 400°F (205°C), (MT option not
UL, CSA, ATEX or SAA).
Pressure Limit: Brass body 1000 psig (69 bar), 316SS
body 2000 psig (138 bar). Standard float rated 100 psig
(6.9 bar). For other floats see options on "Options/Accessories"
page.
Enclosure Rating: Weatherproof and explosion-proof.
Listed with UL and CSA for Class I, Groups C and D; Class
II, Groups E, F, and G. ATEX
0344
II 2 G EEx d IIB T6 -20°C=Tamb=75°C, EC-Type
Certificate No: KEMA 03 ATEX 2383. SAA: Exd II C T6 (T amb=60°C).
IP66 C1 I, Zone I. Also FM approved.
Switch Type: SPDT snap switch standard, DPDT snap
switch optional.
Electrical Rating: UL, FM, ATEX and SAA models: 10A
@ 125/250 VAC. CSA models: 5A @ 125/250 VAC; 5A res., 3A
ind. @ 30 VDC. MV option: 1A @ 125 VAC; 1A res., .5A ind.
@ 30 VDC. MT option: 5A @ 125/250 VAC. (MT and MV options
not UL, CSA, FM, ATEX or SAA.).
Electrical Connection: UL and CSA models: 16 AWG,
6" (152 mm) long. ATEX and SAA units: terminal block.
Process Connection: 1-1/2" male NPT standard, 2-1/2"
male NPT required for optional floats.
Mounting Orientation: Horizontal installation standard,
optional vertical top mount.
Weight: 4 lb 9 oz (2.07 kg).
Dead Band: 3/4" (19 mm) for standard float.
Specific Gravity: 0.7 minimum with standard float.
For other floats see options on "Options/Accessories" page.
Agency Approvals: UL, CSA, FM, CE and ATEX.
OPTIONS -- Consult
Factory for Pricing
-D DPDT Contacts.
-MV Gold Plated Contact option for dry circuits.
(See electrical rating on "Specifications" page, no listings
or approvals).
-MT High Temperature option rated 400°F (204°C).
(See electrical rating on "Specifications" page, no listings
or approvals).
-TRI Time Delay Relay option for increasing flow
with 2 SPDT contacts, adjustable from 0-1 to 0-31 minutes.
(No listings or approvals.)
-TRD Time Delay Relay option for decreasing flow
with 2 SPDT contacts, adjustable from 0-1 to 0-31 minutes.
(No listings or approvals.)
-316 316SS Magnet Keeper option to replace standard
430SS.
-AT ATEX approved construction.
-SAA SAA approved construction.
-TOP Top Mounted option for vertical flange installation
(distance from flange face to centerline of float to be
specified, 20" [508 mm] maximum).
OPTIONAL FLOATS (all 2-1/2" spherical):
-50 304SS Float rated 50 psig (3.5 bar) and 0.5 min.
s.g. (2-1/2" spherical).
-150 316SS Float rated 150 psig (10.3 bar) and 0.7
min. s.g. (2-1/2" spherical).
-300 304SS Float rated 300 psig (20.7 bar) and 0.7
min. s.g. (2-1/2" spherical).
NOTE: Consult factory for price and availability
of fittings for L4 installation. Thredolets, bushings, and
flanges are available in a variety of sizes and materials.
FEATURES
- Leak proof body machined from bar stock
- Choice of floats dependant on maximum pressure and
specific gravity
- Weatherproof, designed to meet NEMA 4
- Explosion-proof (listings included on "Specifications"
page)
- Installs directly and easily into tank with a thredolet
or flange (see application drawings on "Dimensional
Drawing" page)
- Electrical assembly can be easily replaced without
removing the unit from the installation so that the
process does not have to be shut down
- Horizontal installation or optional top mount vertical
installation