Temperature Indicators
 









The Series LCI308 and LCI408 Panel Meter Indicators offer flexibility and value in a standard 1/8 DIN package. This family of indicators offers input availability for virtually all types of process measurement.

The LCI308 offers a 4-3/4 digit display scalable to ±32,000 counts. This flexible indicator is available for Process Inputs (0-10 VDC, 4-20 mA, etc.), Temperature Inputs (Thermocouple Types J, K, T, and DIN RTD), Timer/Counter type, and Load Cell (strain gauge) Inputs.

The LCI408 has a universal input that accepts the Process, Temperature, and Load Cell inputs of the LCI308, plus a Potentiometer input. The full 5-digit display can be scaled between ±99999 counts. The dual display allows simultaneous display of the measured value plus other values such as peak or valley.

Options include relay and transistor set point outputs, BCD Parallel output, RS-232/RS-485 computer communications, and 4 to 20 mA analog retransmission.


SPECIFICATIONS
Inputs: Process, temperature (T/C & RTO), frequency/counter, load cell (dependent on model number).
Input Impedance:
Process: Voltage, 1 MO; current, 12.1O.
Load Cell: 100 MO for 300 mV, 1 MW for 30 mV.
Display: 5-digit, 7 segment, 14 mm red with a fixed decimal point. 14 LEDs (programming & control).
Accuracy:
LCI308: ±0.1% of reading (except temperature inputs).
Thermocouples: ±0.4% of reading for types J, K, T, & E / ±.05% of reading for types R & S.
RTD: ±0.2% of reading.
LCI408: ±0.1% of reading.
Supply Voltage: 115/230 VAC 50/60 Hz ±10%.
Power Consumption: 3W max.
Weight: 8 oz (250 g).
Front Panel Rating: IP65 (Type 4X).
Agency Approvals: CE.

INPUT RANGES

Model Number
Range °F
Range °C
Type J Thermocouple
-58.0 to 1472.0
-50.0 to 800
Type K Thermocouple
-58.0 to 2282.0
-50.0 to 1250.0
Type T Thermocouple
-328.0 to 752.0
-200 to 400.0
Type RT Thermocouple
32.0 to 3182.0
0.0 to 1750.0
Type S Thermocouple
-58.0 to 3182.0
-50.0 to 1750.0
Type E Thermocouple
-58.0 to 1832.0
-50.0 to 1000.0
100 Ohm Plt. 0.00385 DIN RTD
-328 to 1472.0
-200 to 800.0
100 Ohm Plt. 0.00392 NIST RTD
-328 to 1607
-200 to 875
Process (Includes excitation power supply)
±10 mV
Scalable Units from -32000 to 32000 (LCI308); -99999 to 99999 (LCI408)
±20 mV
Scalable Units from -1999 to 9999
Digital - Frequency/Counter (Includes excitation power supply)
0.1 to 25,000 Hz
Count up/down 10,000 Hz (LCI308)
Potentiometer
Resolution to 0.001% (LCI408)
Load Cell (includes excitation power supply)
±30 mVDC

ACCESSORIES -- See "Ordering" Pages

The LCIA-01 Dual Relay Output Option Card plugs in most of the LCI108 and LCI108J Series, and all of the LCI208, LCI308, and LCI408 Series panel meter indicators and controls. This handy card adds two 8 Amp single pole double throw outputs to a panel meter.


SPECIFICATIONS
Relay Output: 2 SPDT relays rated at 8 A @ 250 VAC resistive.
Maximum Power: 2000 VA, 192 W.
Maximum Voltage: 250 VAC, 150 VDC.
Contact Resistance: 3mO maximum.
Output Response Time: 10 ms maximum.

The LCIA-02 Quad Relay Output Option Card plugs in the LCI208, LCI308, and LCI408 Series panel meter indicators and controls. This handy card adds four 0.2 Amp single pole single throw outputs to a panel meter.

SPECIFICATIONS
Relay Output: 4 SPDT relays rated at 0.2 A @ 250 VAC resistive.
Maximum Power: 25 VA, 192 W.
Maximum Voltage: 250 VAC, 150 VDC.
Contact Resistance: 200mO maximum.
Output Response Time: 6 ms maximum.

The LCIA-03 Quad Transistor Output Option Card plugs in the LCI208, LCI308, and LCI408 Series panel meter indicators and controls. This handy card adds four NPN transistor outputs to a panel meter.

SPECIFICATIONS
Relay Output: 4 NPN Transistors rated at 50 mA @ 50 VDC max.
Leakage Current: 100µ max.
Output Response Time: 1 ms maximum.

The LCIA-04 Quad Transistor Output Option Card plugs in the LCI208, LCI308, and LCI408 Series panel meter indicators and controls. This handy card adds four PNP transistor outputs to a panel meter.

SPECIFICATIONS
Relay Output: 4 PNP Transistors rated at 50 mA @ 50 VDC max.
Leakage Current: 100µ max.
Output Response Time: 1 ms maximum.

The LCIA-05 Isolated Analog Retransmission Option Card plugs in the LCI308 and LCI408 Series panel meter indicators and controls. This handy card adds an analog retransmission output to a panel meter. The output may be selected as either 0 to 10 VDC or 4 to 20 mA DC.

SPECIFICATIONS
Output: Selectable 0 to 10 VDC into 500 ohms minimum, 4 to 20 mA DC into 800 ohms maximum.
Resolution: 12 bits.
Accuracy: 0.1% of full scale ±1 bit.
Response Time: 60 ms maximum.
Thermal Drift: 0.2 mV/°C; 0.5µA/°C.

The LCIA-07 BCD Output Option Card plugs in the LCI308 and LCI408 Series panel meter indicators and controls. This handy card adds a BCD output to a panel meter.

SPECIFICATIONS
Output: 5-1/2 digits Tri-state logic for 5V TTL or 24 VDC signals.
Data Transfer Time: 2 ms.

The LCIA-08 RS-232 Serial Communication Option Card plugs in the LCI308 and LCI408 Series panel meter indicators and controls. This handy card adds RS-232 Serial Communications to a panel meter.

SPECIFICATIONS
Output: RS-232-C, full duplex, 4 wire, via RJ-11 connector.
Protocol: Selectable ISO1745 (ASCII) or Modbus® RTU Protocol.
Baud Rates: 1200 or 19200 baud, selectable.
Address Range: 0 to 99.

The LCIA-09 RS-485 Serial Communication Option Card plugs in the LCI308 and LCI408 Series panel meter indicators and controls. This handy card adds RS-485 Serial Communications to a panel meter.

SPECIFICATIONS
Output: RS-485-C, half duplex, 3 wire, via RJ-11 connector.
Protocol: Selectable ISO1745 (ASCII) or Modbus® RTU Protocol.
Baud Rates: 1200 or 19200 baud, selectable.
Address Range: 0 to 99.

    DIMENSIONAL DRAWING

Lci308-Lci408

     
    CATALOG
    ORDERING
     
 
Pressure
Flow
Air Velocity
Level
Temperature
Valves
Combustion Testing
Data Acquisition
Humidity
Test Equipment
Accessories
ATEX Products