The micropressure
based Series LPI Loop Powered Indicator accepts
a 4-20 mA input signal and displays the associated process
variable such as pressure, level, flow, temperature or relative
humidity. Local or remote indication of process variable
can be viewed on the bright red four-digit LED. The user
can quickly modify the instrument configuration via three
push buttons. Program input/output scaling, engineering
units, offset, decimal point position, and password protection.
The Series LPI contains several linearizations which can
be applied to the display including straight linear, square
root, x 3/2, x 5/2, or a user defined 19 segment linearization
curve. The indicator is housed in a NEMA 4X (IP65) polycarbonate
enclosure with a 1/2" female NPT side port.
SPECIFICATIONS
Input: 4 to 20 mA.
Maximum Input Current: 100 mA for 1 minute.
Accuracy: ±0.02% of full scale.
Stability: Zero: 0.002%/°C; Span: 100 ppm/°C.
Power Requirements: 2-wire 4-20 mA loop powered.
Display: 4-digit, 7.6 mm (high) red LED.
Maximum Display Range: -1999 to 9999.
Ambient Operating Temperature: -4 to 167°F (-20 to
75°C).
Storage Temperature: -58 to 185°F (-50 to 85°C).
Weight: 6.0 oz (170 g).
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE.
|