Temperature Indicators
 









The micropressure based Series LPI Loop Powered Indicator accepts a 4-20 mA input signal and displays the associated process variable such as pressure, level, flow, temperature or relative humidity. Local or remote indication of process variable can be viewed on the bright red four-digit LED. The user can quickly modify the instrument configuration via three push buttons. Program input/output scaling, engineering units, offset, decimal point position, and password protection. The Series LPI contains several linearizations which can be applied to the display including straight linear, square root, x 3/2, x 5/2, or a user defined 19 segment linearization curve. The indicator is housed in a NEMA 4X (IP65) polycarbonate enclosure with a 1/2" female NPT side port.


SPECIFICATIONS
Input: 4 to 20 mA.
Maximum Input Current: 100 mA for 1 minute.
Accuracy: ±0.02% of full scale.
Stability: Zero: 0.002%/°C; Span: 100 ppm/°C.
Power Requirements: 2-wire 4-20 mA loop powered.
Display: 4-digit, 7.6 mm (high) red LED.
Maximum Display Range: -1999 to 9999.
Ambient Operating Temperature: -4 to 167°F (-20 to 75°C).
Storage Temperature: -58 to 185°F (-50 to 85°C).
Weight: 6.0 oz (170 g).
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE.

    DIMENSIONAL DRAWING

Lpi

     
    SERVICE MANUAL
    CATALOG
    ORDERING
     
 
Pressure
Flow
Air Velocity
Level
Temperature
Valves
Combustion Testing
Data Acquisition
Humidity
Test Equipment
Accessories
ATEX Products