PBLT2 and
PBLTX Submersible Level Transmitters are manufactured
for years of trouble free service in the harshest applications.
Both measure the height of liquid above the position in
the tank referenced to atmospheric pressure. The transmitter
consists of a piezoresistive sensing element, encased in
a 316 SS housing. Perfect for wastewater and slurry applications
with features to protect the unit from these demanding applications.
Large diameter 316 SS diaphragm seal is non-clogging and
damage resistant to floating solids.
The PBLT2 incorporates lightning and surge protection utilizing
dual arrestor technology, grounded to case, eliminating
both power supply surges and lightning ground strike transients
(surge protection is not guaranteed and is not covered by
warranty). The PBLTX is UL approved intrinsically safe for
use in hazardous locations when used with proper barrier.
Units comes equipped with a 270-pound tensile strength shielded
and vented cable. Ventilation tube in the cable automatically
compensates for changes in atmospheric pressure above the
tank. The vent is protected with a maintenance free filter
eliminating particulate or water droplets from entering
the transducer.
FEATURES
• Excellent chemical compatibility with 316 construction
and ETFE cable
• Lightning and surge protection on PBLT2 models
• Maintenance free vent filter
• UL approved intrinsically safe on PBLTX models
• Large diameter, non-clogging, damage resistant,
316 SS diaphragm seal
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: 316 SS, 316L SS, Buna-N,
cable: ETFE or polyurethane.
Accuracy: ±0.25% full scale (includes
linearity, hysteresis, and repeatability).
Temperature Limit: PBLT2: 0 to 200°F
(-18 to 93°C), PBLTX: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range: PBLT2: 0
to 180°F (-18 to 82°C), PBLTX: 0 to 176°F (-18
to 80°C).
Thermal Effect: ±0.02% FS/°F.
Pressure Limit: 2X full scale.
Power Requirement: PBLT2: 13 to 30 VDC,
PBLTX: 10 to 28 VDC.
Output Signal: 4 to 20 mA DC, two wire.
Response Time: 50 msec.
Loop Resistance: 900 ohms.
Electrical Connection: Wire pigtail.
Mounting Orientation: Suspended in tank
below level being measured.
Weight: 4.3 lb (2.0 kg).
Electrical Protection: PBLT2: Lightning
and surge protection, PBLTX: none.
Agency Approvals: PBLT2: None, PBLTX: CE,
UL intrinsically safe for Class I, Div. 1, Groups A, B,
C, D; Class II, Div. 1, Groups E, F, G; Class III, Div.
1. (According to control drawing 01-700797-00)
APPLICATIONS
• Wastewater: sludge pits, clarifiers, digesters;
alum tanks; chemical storage tanks; oil tanks; lime slurry;
slumps; reservoirs.
OPTIONS
Intrinsically Safe Approval- Change model number from PBLT2
to PBLTX Custom ranges or Cable Lengths- Contact the factory
for pricing.
ACCESSORIES
MTL5041, intrinsically safe galvanic isolator
MTL7706, intrinsically safe zener barrier
Model Number |
Range psi
(ft wc) [m wc] |
Cable Length
ft (m) |
Cable Type |
PBLT2-5-40
PBLT2-10-40
PBLT2-15-60
PBLT2-20-60
PBLT2-5-40-PU
PBLT2-10-40-PU
PBLT2-15-60-PU
PBLT2-20-60-PU |
5 (11.54) [3.52]
10 (23.09) [7.04]
15 (34.63) [10.56]
20 (46.18) [14.08]
5 (11.54) [3.52]
10 (23.09) [7.04]
15 ( 34.63) [10.56]
20 (46.18) [14.08] |
40 (12.2)
40 (12.2)
60 (18.3)
60 (18.3)
40 (12.2)
40 (12.2)
60 (18.3)
60 (18.3) |
ETFE
ETFE
ETFE
ETFE
Polyurethane
Polyurethane
Polyurethane
Polyurethane |