The
Rate-Master® Flowmeter line
of direct reading precision flowmeters incorporates many
unique user features at moderate cost. These low cost flowmeters
are ideal for general use.
Easy to
read design - The direct reading scales eliminate
troublesome conversions. The scales are brushed aluminum,
coated with epoxy and the graduations are on both sides
of the indicating tube. Special integral flow guides stabilize
the float throughout the range to keep it from hunting or
wandering in the bore. The float is highly visible against
a white background.
Construction
assures accuracy - All Rate-Master® flowmeter
bodies are injection molded of tough, clear, shatter-proof
polycarbonate plastic around a precision tapered pin. The
result is accurate and repeatable readings. The single piece
plastic body is mounted to a stainless steel back bone into
which pipe thread inserts are welded to absorb piping torque.
Precision metering valves of brass or stainless steel (specify
BV or SSV on order) are available as an optional extra and
permit precise flow adjustments. For vacuum applications,
Model RMA units are available with top mounted valves (specify
TMV). The small Series RMA models are accurate within ±4%
of full scale reading; Series RMB within ±3%; large Series
RMC within ±2%.
Installation
is simple - The Rate-Master® flowmeter can be
neatly through - panel mounted to keep flow tube centers
in the same plane as the panel surface or surface mounted
on the panel by means of tapped holes in the backbone. When
through-panel mounted, the bezel automatically positions
the instrument at the correct depth in the panel cutout.
Surface mounted units can also be held in place by the piping.
All mounting hardware plus installation and operating instructions
are included.
Easy-to-Interchange
bodies - Within a given Series Rate-Master® flowmeter
bodies can be instantly interchanged. Simply "unplug" the
body from backbone and replace it with another. "O" rings
provide a tight seal on inlet and outlet. Piping remains
undisturbed. Interchangeability is useful where different
scale ranges are sometimes required at the same location
in the laboratory or plant.
Cleaning
is easy - To release the plastic flowmeter body
from the stainless steel backbone, just remove four screws.
Pipe thread flow connections remain undisturbed. Remove
the slide cover and the plug ball stop, clean the flow tube
with soap and water and reassemble. It’s that simple.
SPECIFICATIONS
Service: Compatible gases and liquids.
Wetted Materials: Body: Polycarbonate; O-ring: Neoprene
& Buna-N; Metal Parts: Stainless steel (except for optional
brass valve); Float: Stainless steel, black glass, aluminum,
K monel, tungsten carbide depending on range.
Temperature Limit: 130°F (54°C).
Pressure Limit: 100 psi (6.9 bar).
Accuracy: RMA: 4%; RMB: 3%; RMC: 2% of full scale.
Process Connection: RMA: 1/8"; RMB: 1/4"; RMC: 1/2"
female NPT.
Weight: RMA: 4 oz (113.4 g); RMB: 13 oz (368.5 g);
RMC: 39 oz (1105.6 g).
CAUTION
Dwyer® Rate-Master® flowmeters are designed to provide
satisfactory long term service when used with air, water,
or other compatible media. Refer to factory for information
on questionable gases or liquids. Caustic solutions, anti-freeze
(ethylene glycol) and aromatic solvents should definitely
not be used.