SBLT Submersible
Level Transmitter is manufactured for years of
trouble free service. The transmitter consists of a bonded
foil, strain gauge, sensing element, encased in 316 SS housing.
Superior lightning and surge protection utilizing dual arrestor
technology, grounded to case, eliminating both power supply
surges and lightning ground strike transients. Bullet nose
design protects diaphragm from damage. Comes equipped with
a 220-pound tensile strength, shielded, vented, Polyurethane
cable. Ventilation tube in the cable automatically compensates
for changes in atmospheric pressure above the tank. The
vent is protected with a maintenance free filter eliminating
moisture collection in the transducer. The vent filter is
a much superior design to transmitters with desiccant tubes
that need to be replaced and bladder bags that can throw
off readings and add extra cost.
APPLICATIONS
Well monitoring; Ground water monitoring; Environmental
remediation; Surface water monitoring; Down hole; Water
Tanks.
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Body: 316 SS, Cable: Polyurethane,
Bullet Nose: PVC.
Accuracy: ±0.20% of full scale.
Temperature Limits: -40 to 150°F (-40 to 65.6°C).
Compensated Temperature Range: 0 to 140°F (-17.8
to 60°C).
Pressure Limit: 1.5X full scale range.
Thermal Effect: Less than ±2.0% full scale per 100°F.
Power Requirement: 9 to 36 VDC.
Output Signal: 4 to 20 mA DC, 2-wire.
Response Time: <5 ms.
Loop Resistance: 750 ohms at 24 VDC.
Electrical Connections: Wire pigtail.
Mounting Orientation: Suspended in tank below level
being measured. Can be placed on the bottom of the tank
on its side.
Standard Features: Calibration certificate.
Weight: 3.5 lb (1.59 kg).
Electrical Protection: Dual transient lightning and
surge arrestors exceeding FM approved I/S and meet EMA/RFI
standards Mil-Std 461/462 and ground to transducer case.
|