Totalizers
 

 

Monitor flow rate or total flow with Model TM2 Flow Totalizer. Unit features a four digit flow rate display and an eight digit totalizing display with a programmable, five position decimal point. Easily toggle between rate and total with front-panel push-button. Use scaling factor to define flow rate in engineering units such as ml/min, l/min, or gal/hr.

SPECIFICATIONS
Input: 7.5 VDC max. pulse.
Accuracy: ±0.2%.
Input Impedance: 27 kO at 3 VDC.
Totalizer Type: UP count.
Rate Indication Type: Frequency.
Count Input Speed: 10 kHz @ 50% duty cycle.
Totalizing Range: 0.0001 to 100.0000 with five position decimal point.
Rate Indication Range: 0.001 to 9999 (five position decimal point).
Update Time: 0.7 seconds.
Display: 8-digit LCD, 7/16" H.
Temperature Limits: 32 to 131°F (0 to 55°C).
Housing Material: Cycolac X-17.
Power: One 3V lithium battery (included).
Average Battery Life: Approximately 5 years.
Weight: 1 lb (0.5 kg).
Agency Approvals: CE.

 
    DIMENSIONAL DRAWING

Tm2

    SERVICE MANUAL
 
CATALOG
    ORDERING
     
 
Pressure
Flow
Air Velocity
Level
Temperature
Valves
Combustion Testing
Data Acquisition
Humidity
Test Equipment
Accessories
ATEX Products